The Boltzmann annealing mode
This is the default mode for QS (ie. when the -auto flag is defined).
For this mode, the temperature T at time step t of the minimisation is
given by
T = T0/log(t) where T0 is the starting temperature for the
simulation (can be determined automatically with the keyword
DETErmine_bath). This mode implies a constant move-size control as
described for the constant temperature run.